Data from: Development of an international external quality assurance program for HIV-1 incidence using the Limiting Antigen Avidity assay

Public

  • Laboratory assays for identifying recent HIV-1 infections are widely used for estimating incidence in cross-sectional population-level surveys in global HIV-1 surveillance. Adequate assay and laboratory performance are required to ensure accurate incidence estimates. The NIAID-supported External Quality Assurance Program Oversight Laboratory (EQAPOL) established a proficiency testing program for the most widely-used incidence assay, the HIV-1 Limiting Antigen Avidity EIA (LAg), with US Centers for Disease Control and Prevention (CDC)-approved kits manufactured by Sedia Biosciences Corporation and Maxim Biomedical. The objective of this program is to monitor the performance of participating laboratories. Four rounds of blinded external proficiency (EP) panels were distributed to up to twenty testing sites (7 North American, 5 African, 4 Asian, 2 South American and 2 European).
    These panels consisted of ten plasma samples: three blinded well-characterized HIV-1-seropositive samples that were included as replicates and an HIV-negative control. The seropositive samples spanned the dynamic range of the assay and are categorized as either recent or long-term infection. Participating sites performed the assay according to manufacturers’ instructions and completed an online survey to gather information on kit manufacturer, lot of kit used, laboratory procedures and the experience of technicians. On average, fifteen sites participated in each round of testing, with an average of four sites testing with only the Maxim assay, seven testing with only the Sedia assay and five sites utilizing both assays. Overall, the Sedia and Maxim assays yielded similar infection status categorization across the laboratories; however, for most of the nine HIV+ samples tested, there were significant differences in the optical density readouts, ODn (N=8) and OD (N=7), between LAg kit manufacturers (p < 0.05 based on mixed effects models. The EQAPOL LAg program is important for monitoring laboratory performance as well as detecting variations between manufacturers of HIV-1 incidence assays.
    ... [Read More]

Total Size
3 files (118 KB)
Data Citation
  • Keating, S., Rountree, W., Grebe, E., Pappas, A. L., Stone, M., Hampton, D.,...Busch, M. P. (2019). Data from: Development of an international external quality assurance program for HIV-1 incidence using the Limiting Antigen Avidity assay. Duke Digital Repository. https://doi.org/10.7924/r4ff3r13q
DOI
  • 10.7924/r4ff3r13q
Publication Date
ARK
  • ark:/87924/r4ff3r13q
Type
Format
Related Materials
Contact
Title
  • Data from: Development of an international external quality assurance program for HIV-1 incidence using the Limiting Antigen Avidity assay
This Dataset
Usage Stats